Home

CAFCO® FENDOLITE® M-II

 

Product Characteristics
Short form application guide
MSDS
UL Design Table

 

CAFCO<sup>®</sup> FENDOLITE<sup>®</sup> M-II
CAFCO® FENDOLITE® M-II is a single package, factory controlled Spray-Applied Fire Resistive Material (SFRM) based on vermiculite and portland cement, requiring only the addition of water as an activator. It is specifically developed for spray application to structural steel such as columns, beams, steel vessels and skirts in exterior environments and interior situations where higher levels of abrasion resistance and hardness are necessary. CAFCO FENDOLITE TG has been developed for application by trowel in areas where spraying is impractical or not permitted.

Although CAFCO FENDOLITE M-II is lightweight, thus significantly reducing dead load, it is also highly durable and resistant to cracking or spalling under mechanical impact. CAFCO FENDOLITE may be used in either boxed or contour designs, and the finish may be spray-textured or troweled smooth.

CAFCO FENDOLITE M-II and CAFCO FENDOLITE TG are classified by Underwriters Laboratories for up to 4 hours protection in accordance with the Rapid Rise Fire Test (UL 1709). This fire test was developed to provide a means to evaluate materials intended for use in those areas, such as petrochemical production facilities, which would develop temperatures at a more rapid rate than conventional structures. With UL 1709, the furnace temperature rises from ambient to 2000°F (1093°C) within five minutes. Only materials tested and classified in accordance with UL 1709 can be used where the risk of a hydrocarbon fire exists.

FEATURE AND BENEFITS:
• Spray or Trowel Applied
• Lightweight formulation (approximately one-third the weight of concrete)
• Excellent physical performance characteristics
• Highly Durable
• Resistant to cracking and spalling under impact
• Ready to use with the addition of water
• UL Investigated for Exterior Use
• IBC/ICC Approved, (ICC ESR 1649)
• Proven material with over 25 years of service

TESTS AND APPROVALS:
CAFCO FENDOLITE M-II satisfies the requirements of the following:
• Underwriters Laboratories - Up to 4 hour fire
protection in accordance with ASTM E119 (UL 263) and UL 1709
• UK - Up to 4 hour fire protection in accordance
with BS 476, Parts 20-21: 1987 Appendix D
• Efectis Nederland BV - Tested to Rijkswaterstaat (RWS) Fire Test Curve
• Factory Mutual Approved - LP Gas Steel Storage Vessels and Process Structures with Hose Stream
• GASAFE - LPG Storage Vessels
• Liquid Nitrogen Immersion Test
• International Standard ISO 834
• Lloyds Register - Structural Steel Hydrocarbon Fire Protection System (Jet Fire Protection)
• Three Bar Overpressure Blast Explosion Testing with Subsequent UL 1709 Fire Test
• International Code Council (ICC) - ESR 1649




To view some of the documents on this site you will need the lastest version of Acrobat Reader.
Click here to download a free version of this software.